Our range of gas sensors, circuitry, housed measuring systems and limit monitors are listed below. To download a Datasheet, please click on the appropriate link. To view these files you will need Adobe Acrobat. For a downloadable product listing, please see: Product Listing 2012.
If you are unable to find the gas or product you require and need assistance, please contact us. We will be pleased to find the solution to your gas detection requirements.
Ammonia NH3 - Carbon Dioxide CO2 - Carbon Monoxide CO - Chlorine Cl2 Flammable Gases LEL - Hydrogen H2 - Hydrogen Sulphide H2S - Nitrogen Dioxide NO2 |
|
Gas |
Product Type |
Sensor Name |
Measurement Range |
Part Number |
Datasheets available for download |
| Sensor with transmitter |
NH3 4-20mA transmitter including sensor |
0 100 ppm |
2112B0311 |
||
|
|
Measuring system |
NH3 gas measuring system NH3 sensor, 4-20mA transmitter and installation kit in aluminium housing |
0 100 ppm |
2112B0312 |
-
Datasheet - Manual |
|
Carbon Dioxide
CO2
|
Sensor with transmitter |
C1
ultra low power (3.5mW) miniature infrared CO2 sensor with RS232
transmitter or analogue voltage output
Optional temperature
and humidity output available |
Standard: |
2112BC1 or 2112BC1-V (analogue voltage output) |
-
Datasheet - Manual |
| Sensor with transmitter |
C2
ultra low power (3.5mW) miniature infrared CO2 sensor with RS232
transmitter or analogue voltage output
Optional temperature
and humidity output available
|
Standard: |
2112BC2
or 2112BC2-V
|
-
Datasheet - Manual - Analogue voltage option manual - Example Applications |
|
|
|
Sensor with transmitter |
C3 standard infrared CO2 sensor with 4-20mA transmitter |
Standard: |
2112B7000 |
- Datasheet |
| Sensor with transmitter |
C3 standard infrared CO2 sensor with 4-20mA transmitter |
Standard: |
2112B7050 |
- Datasheet | |
| Measuring system |
Indoor air quality |
0 3000 ppm |
2112B8000 |
- Datasheet | |
| Measuring system |
Luftgόte mobile indoor air quality infrared CO2 monitor with traffic light option including power supply unit 100-250V a.c. 50Hz |
0 3000 ppm |
2112B8000-TLM |
- Datasheet | |
| Measuring system |
Luftgόte two relay indoor air quality infrared CO2 monitor with traffic light option. Power supply: 24V d.c. |
0 3000 ppm |
2112B8000-TLR |
- Datasheet | |
| Measuring system |
CO2 gas measuring system heavy duty C3 infrared CO2 sensor with 4-20mA transmitter in aluminium housing. PG11 cable gland |
Standard: |
2112B9000 |
- Datasheet | |
| Measuring system |
CO2 gas measuring system heavy duty C3 infrared CO2 sensor with 4-20mA transmitter in aluminium housing. PG11 cable gland |
Standard: |
2112B9050 |
- Datasheet | |
| Measuring system |
CO2 gas measuring system heavy duty C3 infrared CO2 sensor suitable and certified for use in hazardous areas Zone 2 in aluminium housing. Ex e cable gland |
Standard:
Optional:
|
2112B9055 |
- Datasheet | |
| Measuring system |
CO2 gas warning system complete infrared CO2 sensing system with alarm. This system is particularly suitable for areas of CO2 gas storage, such as beer cellars. |
Standard: |
2112B0600 |
- Datasheet | |
| Accessories |
Test and calibration software for C3 standard CO2 infrared sensors |
N/A |
2112B9075 |
- Datasheet | |
| Accessories |
Data cable 2.5 metres for test/calibration software for C3 standard CO2 infrared sensors |
N/A |
2112B9085 |
- Datasheet | |
| Accessories |
Test Gas Cap and installation ring for C3 standard CO2 infrared sensors |
N/A |
2112B1011 |
||
|
|
ECO-Sure
|
0 500 ppm |
2112B3000 |
- Datasheet | |
| Sensor with transmitter |
ECO-Sure (2e) 4-20 mA transmitter including sensor |
Standard:
|
2112B1005 |
- Datasheet/ Manual | |
| Accessories |
Eco-Sure (2e) transmitter installation kit (sensor holder; o-ring; sinter disc; installation ring) |
N/A |
2112B1002 |
- Datasheet | |
| Measuring system |
CO
gas measuring system ECO-Sure (2e) sensor, |
Standard: |
2112B1013 |
- Datasheet | |
| Measuring system |
CO Detector Head for Car Park Monitoring System - 2 alarm or 4 alarm threshold versions available. Note: The 2 alarm version is perfect for smaller car parking areas. The 4 alarm version is utilised in larger areas with the requirement for 4 alarm thresholds. |
0 300 ppm |
2112BGMS-TRL 2112BGMS-TRL4 |
-
2 Alarm Overview - 2 Alarm Datasheet - 2 Alarm Manual |
|
| Measuring system |
Relay
Unit for
|
N/A |
2112BGMS-RZ |
-
Overview - Datasheet - Manual - Simulation |
|
| Sensor |
ECO-Sure CO (2e) LXH version sensor (low Hydrogen cross-sensitivity) |
0 200 ppm |
2112B3008 |
- Datasheet | |
| Sensor with transmitter |
Eco-Sure
(2e) LXH version |
Standard: |
2112B1006 |
- Datasheet | |
| Accessories |
Eco-Sure (2e) LXH version transmitter installation kit |
N/A |
2112B1003 |
||
| Measuring system |
CO
gas measuring system |
Standard: |
2112B1014 |
||
| Sensor |
SureCell CO (M) sensor |
0 1000 ppm |
2112B2003 |
- Datasheet | |
| Sensor with transmitter |
SureCell CO (M) 4-20 mA transmitter including sensor |
0
1000 ppm |
2112B1020 |
- Datasheet | |
|
|
Measuring system |
CO gas measuring system SureCell CO (M) sensor, 4-20 mA transmitter and installation kit in aluminium housing |
0 1000 ppm |
2112B1023 |
-
Datasheet - Manual |
|
|
Accessories |
SureCell
CO (M)
|
N/A |
2112B1022 |
|
|
|
Sensor |
SureCell CO (H) sensor |
0 500 ppm |
2112B2004 |
- Datasheet |
|
|
Sensor |
CO SS sensor |
0 4000 ppm |
2112B010440 |
- Datasheet |
| Sensor |
SureCell Cl2 sensor |
0 20 ppm |
2112B2035 |
- Datasheet | |
|
|
Sensor with transmitter |
SureCell Cl2 4-20 mA transmitter including sensor |
0
20 ppm |
2112B1035 |
- Datasheet |
|
|
Accessories |
SureCell
Cl2
|
N/A |
2112B1022 |
|
|
|
Measuring system |
Cl2 gas measuring system SureCell Cl2 sensor, 4-20 mA transmitter and installation kit in aluminium housing |
0 20 ppm |
2112B1018 |
-
Datasheet - Manual |
| Flammable Gases LEL | Sensor |
CAT16 pellistor elements |
0 100 % LEL |
2111B2016 |
- Datasheet |
| Sensor |
CAT25 pellistor elements |
0 100 % LEL |
2111B2125 |
- Datasheet | |
| Sensor |
Zellpell sensor (CAT25 elements built into certified housing) |
0 100 % LEL |
2118B0106 |
- Datasheet | |
| Sensor with transmitter |
Zellpell 4-20mA transmitter including sensor and installation kit |
0 100 % LEL |
2112B1000 |
- Datasheet / Manual | |
| Accessories |
Zellpell transmitter installation kit |
N/A |
2112B1003 |
||
| Measuring system |
Flammable
gas monitoring system Zellpell sensor, |
0 100 % LEL |
2112B1004 |
||
| Hydrogen H2 | Sensor |
H2 SS sensor |
0
2% Volume
|
Raw
sensor:
Micro
sensor:
4
series sensor: |
-
Technology - Datasheet
|
| Sensor with transmitter |
H2 SS 1-5V transmitter including sensor |
0
2% Volume |
2112B013410 |
- Datasheet | |
| Sensor with transmitter |
H2 SS 4-20mA transmitter including sensor |
0
2% Volume |
2112B24421 |
||
| Accessories |
USB gas sensor stick for H2 SS sensor in USB housing with software |
N/A |
2112B051001 |
||
| Accessories |
USB gas sensor stick for 4 series H2 SS sensor with cable and adaptor |
N/A |
2112B051002 |
||
| Measuring system |
H2
measuring system |
0
2% Volume |
2112B0090 |
- Datasheet | |
| Measuring system |
H2
measuring system |
0
2% Volume |
2112B24420 |
- Datasheet | |
| Hydrogen Sulphide H2S | Sensor |
SureCell H2S (L) sensor |
0 200 ppm |
2112B2021 |
- Datasheet |
| Sensor with transmitter |
SureCell H2S (L) 4-20 mA transmitter including sensor |
0
200 ppm |
2112B1015 |
- Datasheet / Manual | |
| Accessories |
SureCell H2S (L) transmitter installation kit |
N/A |
2112B1022 |
||
| Measuring system |
H2S gas measuring system SureCell H2S (L) sensor, 4-20 mA transmitter and installation kit in aluminium housing |
0
200 ppm |
2112B1016 |
-
Datasheet - Manual |
|
| Sensor |
SureCell H2S (M) sensor |
0 100 ppm |
2112B2022 |
- Datasheet | |
| Sensor |
SureCell H2S (H) sensor |
0 100 ppm |
2112B2023 |
- Datasheet | |
| Nitrogen Dioxide NO2 | Sensor |
NO2 2E sensor |
0 20 ppm |
2112B9998 |
- Datasheet |
| Sensor with transmitter |
NO2 4-20mA transmitter including 2E sensor and installation kit |
0 20 ppm |
2112B9999 |
- Datasheet / Manual | |
| Accessories |
NO2
2E
transmitter |
N/A |
2112B1012 |
||
| Measuring system |
NO2 gas measuring system NO2 2E sensor, 4-20mA transmitter and installation kit in aluminium housing |
0 20 ppm |
2112B9995 |
-
Datasheet - Manual |
|
| Sensor |
NO2 SS sensor |
0
100ppm
|
Raw
sensor:
Micro
sensor:
4
series sensor: |
New product - datasheets available shortly | |
| Sensor with transmitter |
NO2 SS 0-5V transmitter including sensor |
0
100ppm |
2112B013450 |
New product - datasheet available shortly | |
| Oxygen O2 | Sensor |
O2 SS sensor |
0
30% Volume |
Raw
sensor:
Micro
sensor: 4 series sensor: 2112B010430 |
-
Technology - Datasheet
|
| Sensor with transmitter |
O2 SS 0-5V transmitter including sensor |
0 30 % Volume |
2112B013430 |
- Datasheet | |
| Sensor |
O2 SL sensor |
0 25 % Volume |
2112B4530 |
- Datasheet | |
| Sensor with transmitter |
O2 SL 4-20mA transmitter including sensor and installation kit |
0 25 % Volume |
2112B4532 |
- Datasheet | |
| Measuring system |
O2
gas measuring system |
0 25 % Volume |
2112B4533 |
-
Datasheet - Manual |
|
|
|
Measuring system |
SO2 gas measuring system SO2 sensor, 4-20mA transmitter and installation kit in aluminium housing |
Standard: |
2112B0075 |
-
Datasheet - Manual |
| Accessories | Accessories |
Test
Gas Cap suitable for all |
N/A |
2112B1010 |
|
| Accessories |
MODBUS Card suitable for all 4-20 mA transmitters |
N/A |
2112B1050 |
-
Datasheet - Manual - Switches - Schematic |
|
| Accessories |
MODBUS Card suitable for all 4-20 mA transmitters in aluminium housing with cabling glands |
N/A |
2112B1055 |
-
Datasheet - Manual - Switches - Schematic |
|
| Accessories |
Gas detection controller (limit monitor) for up to 2 remote 4-20mA transmitters |
N/A |
2112BGWZ-S2 |
-
Datasheet - Manual |
|
| Accessories |
Gas detection controller (limit monitor) for up to 4 remote 4-20mA transmitters |
N/A |
2112BGWZ-S4 |
-
Datasheet - Manual |
|
| Accessories |
Gas detection controller (limit monitor) for up to 6 remote 4-20mA transmitters |
N/A |
2112BGWZ-S6 |
-
Datasheet - Manual |
|
|
|
|
Go to: Top of page |
|
|
|
|
|
|
|
Euro-Gas Management Services Ltd Registered in England No. 602329 Registered Office as above |